// +build linux
|
|
|
|
package systemd
|
|
|
|
import (
|
|
"fmt"
|
|
"io/ioutil"
|
|
"os"
|
|
"path/filepath"
|
|
"strconv"
|
|
"strings"
|
|
"sync"
|
|
"time"
|
|
|
|
systemdDbus "github.com/coreos/go-systemd/dbus"
|
|
systemdUtil "github.com/coreos/go-systemd/util"
|
|
"github.com/godbus/dbus"
|
|
"github.com/opencontainers/runc/libcontainer/cgroups"
|
|
"github.com/opencontainers/runc/libcontainer/cgroups/fs"
|
|
"github.com/opencontainers/runc/libcontainer/configs"
|
|
)
|
|
|
|
type Manager struct {
|
|
mu sync.Mutex
|
|
Cgroups *configs.Cgroup
|
|
Paths map[string]string
|
|
}
|
|
|
|
type subsystem interface {
|
|
// Returns the stats, as 'stats', corresponding to the cgroup under 'path'.
|
|
GetStats(path string, stats *cgroups.Stats) error
|
|
// Set the cgroup represented by cgroup.
|
|
Set(path string, cgroup *configs.Cgroup) error
|
|
}
|
|
|
|
var subsystems = map[string]subsystem{
|
|
"devices": &fs.DevicesGroup{},
|
|
"memory": &fs.MemoryGroup{},
|
|
"cpu": &fs.CpuGroup{},
|
|
"cpuset": &fs.CpusetGroup{},
|
|
"cpuacct": &fs.CpuacctGroup{},
|
|
"blkio": &fs.BlkioGroup{},
|
|
"hugetlb": &fs.HugetlbGroup{},
|
|
"perf_event": &fs.PerfEventGroup{},
|
|
"freezer": &fs.FreezerGroup{},
|
|
"net_prio": &fs.NetPrioGroup{},
|
|
"net_cls": &fs.NetClsGroup{},
|
|
}
|
|
|
|
const (
|
|
testScopeWait = 4
|
|
)
|
|
|
|
var (
|
|
connLock sync.Mutex
|
|
theConn *systemdDbus.Conn
|
|
hasStartTransientUnit bool
|
|
hasTransientDefaultDependencies bool
|
|
)
|
|
|
|
func newProp(name string, units interface{}) systemdDbus.Property {
|
|
return systemdDbus.Property{
|
|
Name: name,
|
|
Value: dbus.MakeVariant(units),
|
|
}
|
|
}
|
|
|
|
func UseSystemd() bool {
|
|
if !systemdUtil.IsRunningSystemd() {
|
|
return false
|
|
}
|
|
|
|
connLock.Lock()
|
|
defer connLock.Unlock()
|
|
|
|
if theConn == nil {
|
|
var err error
|
|
theConn, err = systemdDbus.New()
|
|
if err != nil {
|
|
return false
|
|
}
|
|
|
|
// Assume we have StartTransientUnit
|
|
hasStartTransientUnit = true
|
|
|
|
// But if we get UnknownMethod error we don't
|
|
if _, err := theConn.StartTransientUnit("test.scope", "invalid", nil, nil); err != nil {
|
|
if dbusError, ok := err.(dbus.Error); ok {
|
|
if dbusError.Name == "org.freedesktop.DBus.Error.UnknownMethod" {
|
|
hasStartTransientUnit = false
|
|
return hasStartTransientUnit
|
|
}
|
|
}
|
|
}
|
|
|
|
// Ensure the scope name we use doesn't exist. Use the Pid to
|
|
// avoid collisions between multiple libcontainer users on a
|
|
// single host.
|
|
scope := fmt.Sprintf("libcontainer-%d-systemd-test-default-dependencies.scope", os.Getpid())
|
|
testScopeExists := true
|
|
for i := 0; i <= testScopeWait; i++ {
|
|
if _, err := theConn.StopUnit(scope, "replace", nil); err != nil {
|
|
if dbusError, ok := err.(dbus.Error); ok {
|
|
if strings.Contains(dbusError.Name, "org.freedesktop.systemd1.NoSuchUnit") {
|
|
testScopeExists = false
|
|
break
|
|
}
|
|
}
|
|
}
|
|
time.Sleep(time.Millisecond)
|
|
}
|
|
|
|
// Bail out if we can't kill this scope without testing for DefaultDependencies
|
|
if testScopeExists {
|
|
return hasStartTransientUnit
|
|
}
|
|
|
|
// Assume StartTransientUnit on a scope allows DefaultDependencies
|
|
hasTransientDefaultDependencies = true
|
|
ddf := newProp("DefaultDependencies", false)
|
|
if _, err := theConn.StartTransientUnit(scope, "replace", []systemdDbus.Property{ddf}, nil); err != nil {
|
|
if dbusError, ok := err.(dbus.Error); ok {
|
|
if strings.Contains(dbusError.Name, "org.freedesktop.DBus.Error.PropertyReadOnly") {
|
|
hasTransientDefaultDependencies = false
|
|
}
|
|
}
|
|
}
|
|
|
|
// Not critical because of the stop unit logic above.
|
|
theConn.StopUnit(scope, "replace", nil)
|
|
}
|
|
return hasStartTransientUnit
|
|
}
|
|
|
|
func getIfaceForUnit(unitName string) string {
|
|
if strings.HasSuffix(unitName, ".scope") {
|
|
return "Scope"
|
|
}
|
|
if strings.HasSuffix(unitName, ".service") {
|
|
return "Service"
|
|
}
|
|
return "Unit"
|
|
}
|
|
|
|
func (m *Manager) Apply(pid int) error {
|
|
var (
|
|
c = m.Cgroups
|
|
unitName = getUnitName(c)
|
|
slice = "system.slice"
|
|
properties []systemdDbus.Property
|
|
)
|
|
|
|
if c.Slice != "" {
|
|
slice = c.Slice
|
|
}
|
|
|
|
properties = append(properties,
|
|
systemdDbus.PropSlice(slice),
|
|
systemdDbus.PropDescription("docker container "+c.Name),
|
|
newProp("PIDs", []uint32{uint32(pid)}),
|
|
)
|
|
|
|
// Always enable accounting, this gets us the same behaviour as the fs implementation,
|
|
// plus the kernel has some problems with joining the memory cgroup at a later time.
|
|
properties = append(properties,
|
|
newProp("MemoryAccounting", true),
|
|
newProp("CPUAccounting", true),
|
|
newProp("BlockIOAccounting", true))
|
|
|
|
if hasTransientDefaultDependencies {
|
|
properties = append(properties,
|
|
newProp("DefaultDependencies", false))
|
|
}
|
|
|
|
if c.Memory != 0 {
|
|
properties = append(properties,
|
|
newProp("MemoryLimit", uint64(c.Memory)))
|
|
}
|
|
// TODO: MemoryReservation and MemorySwap not available in systemd
|
|
|
|
if c.CpuShares != 0 {
|
|
properties = append(properties,
|
|
newProp("CPUShares", uint64(c.CpuShares)))
|
|
}
|
|
|
|
if c.BlkioWeight != 0 {
|
|
properties = append(properties,
|
|
newProp("BlockIOWeight", uint64(c.BlkioWeight)))
|
|
}
|
|
|
|
// We need to set kernel memory before processes join cgroup because
|
|
// kmem.limit_in_bytes can only be set when the cgroup is empty.
|
|
// And swap memory limit needs to be set after memory limit, only
|
|
// memory limit is handled by systemd, so it's kind of ugly here.
|
|
if c.KernelMemory > 0 {
|
|
if err := setKernelMemory(c); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
if _, err := theConn.StartTransientUnit(unitName, "replace", properties, nil); err != nil {
|
|
return err
|
|
}
|
|
|
|
if err := joinDevices(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
// TODO: CpuQuota and CpuPeriod not available in systemd
|
|
// we need to manually join the cpu.cfs_quota_us and cpu.cfs_period_us
|
|
if err := joinCpu(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
if err := joinMemory(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
// we need to manually join the freezer, net_cls, net_prio and cpuset cgroup in systemd
|
|
// because it does not currently support it via the dbus api.
|
|
if err := joinFreezer(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
if err := joinNetPrio(c, pid); err != nil {
|
|
return err
|
|
}
|
|
if err := joinNetCls(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
if err := joinCpuset(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
if err := joinHugetlb(c, pid); err != nil {
|
|
return err
|
|
}
|
|
// FIXME: Systemd does have `BlockIODeviceWeight` property, but we got problem
|
|
// using that (at least on systemd 208, see https://github.com/opencontainers/runc/libcontainer/pull/354),
|
|
// so use fs work around for now.
|
|
if err := joinBlkio(c, pid); err != nil {
|
|
return err
|
|
}
|
|
|
|
paths := make(map[string]string)
|
|
for sysname := range subsystems {
|
|
subsystemPath, err := getSubsystemPath(m.Cgroups, sysname)
|
|
if err != nil {
|
|
// Don't fail if a cgroup hierarchy was not found, just skip this subsystem
|
|
if cgroups.IsNotFound(err) {
|
|
continue
|
|
}
|
|
return err
|
|
}
|
|
paths[sysname] = subsystemPath
|
|
}
|
|
m.Paths = paths
|
|
|
|
if paths["cpu"] != "" {
|
|
if err := fs.CheckCpushares(paths["cpu"], c.CpuShares); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (m *Manager) Destroy() error {
|
|
m.mu.Lock()
|
|
defer m.mu.Unlock()
|
|
theConn.StopUnit(getUnitName(m.Cgroups), "replace", nil)
|
|
if err := cgroups.RemovePaths(m.Paths); err != nil {
|
|
return err
|
|
}
|
|
m.Paths = make(map[string]string)
|
|
return nil
|
|
}
|
|
|
|
func (m *Manager) GetPaths() map[string]string {
|
|
m.mu.Lock()
|
|
paths := m.Paths
|
|
m.mu.Unlock()
|
|
return paths
|
|
}
|
|
|
|
func writeFile(dir, file, data string) error {
|
|
// Normally dir should not be empty, one case is that cgroup subsystem
|
|
// is not mounted, we will get empty dir, and we want it fail here.
|
|
if dir == "" {
|
|
return fmt.Errorf("no such directory for %s.", file)
|
|
}
|
|
return ioutil.WriteFile(filepath.Join(dir, file), []byte(data), 0700)
|
|
}
|
|
|
|
func join(c *configs.Cgroup, subsystem string, pid int) (string, error) {
|
|
path, err := getSubsystemPath(c, subsystem)
|
|
if err != nil {
|
|
return "", err
|
|
}
|
|
if err := os.MkdirAll(path, 0755); err != nil {
|
|
return "", err
|
|
}
|
|
if err := writeFile(path, "cgroup.procs", strconv.Itoa(pid)); err != nil {
|
|
return "", err
|
|
}
|
|
|
|
return path, nil
|
|
}
|
|
|
|
func joinCpu(c *configs.Cgroup, pid int) error {
|
|
path, err := getSubsystemPath(c, "cpu")
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
if c.CpuQuota != 0 {
|
|
if err = writeFile(path, "cpu.cfs_quota_us", strconv.FormatInt(c.CpuQuota, 10)); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.CpuPeriod != 0 {
|
|
if err = writeFile(path, "cpu.cfs_period_us", strconv.FormatInt(c.CpuPeriod, 10)); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.CpuRtPeriod != 0 {
|
|
if err = writeFile(path, "cpu.rt_period_us", strconv.FormatInt(c.CpuRtPeriod, 10)); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.CpuRtRuntime != 0 {
|
|
if err = writeFile(path, "cpu.rt_runtime_us", strconv.FormatInt(c.CpuRtRuntime, 10)); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func joinFreezer(c *configs.Cgroup, pid int) error {
|
|
path, err := join(c, "freezer", pid)
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
|
|
freezer := subsystems["freezer"]
|
|
return freezer.Set(path, c)
|
|
}
|
|
|
|
func joinNetPrio(c *configs.Cgroup, pid int) error {
|
|
path, err := join(c, "net_prio", pid)
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
netPrio := subsystems["net_prio"]
|
|
|
|
return netPrio.Set(path, c)
|
|
}
|
|
|
|
func joinNetCls(c *configs.Cgroup, pid int) error {
|
|
path, err := join(c, "net_cls", pid)
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
netcls := subsystems["net_cls"]
|
|
|
|
return netcls.Set(path, c)
|
|
}
|
|
|
|
func getSubsystemPath(c *configs.Cgroup, subsystem string) (string, error) {
|
|
mountpoint, err := cgroups.FindCgroupMountpoint(subsystem)
|
|
if err != nil {
|
|
return "", err
|
|
}
|
|
|
|
initPath, err := cgroups.GetInitCgroupDir(subsystem)
|
|
if err != nil {
|
|
return "", err
|
|
}
|
|
|
|
slice := "system.slice"
|
|
if c.Slice != "" {
|
|
slice = c.Slice
|
|
}
|
|
|
|
return filepath.Join(mountpoint, initPath, slice, getUnitName(c)), nil
|
|
}
|
|
|
|
func (m *Manager) Freeze(state configs.FreezerState) error {
|
|
path, err := getSubsystemPath(m.Cgroups, "freezer")
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
prevState := m.Cgroups.Freezer
|
|
m.Cgroups.Freezer = state
|
|
|
|
freezer := subsystems["freezer"]
|
|
err = freezer.Set(path, m.Cgroups)
|
|
if err != nil {
|
|
m.Cgroups.Freezer = prevState
|
|
return err
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (m *Manager) GetPids() ([]int, error) {
|
|
path, err := getSubsystemPath(m.Cgroups, "cpu")
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
return cgroups.ReadProcsFile(path)
|
|
}
|
|
|
|
func (m *Manager) GetStats() (*cgroups.Stats, error) {
|
|
m.mu.Lock()
|
|
defer m.mu.Unlock()
|
|
stats := cgroups.NewStats()
|
|
for name, path := range m.Paths {
|
|
sys, ok := subsystems[name]
|
|
if !ok || !cgroups.PathExists(path) {
|
|
continue
|
|
}
|
|
if err := sys.GetStats(path, stats); err != nil {
|
|
return nil, err
|
|
}
|
|
}
|
|
|
|
return stats, nil
|
|
}
|
|
|
|
func (m *Manager) Set(container *configs.Config) error {
|
|
for name, path := range m.Paths {
|
|
sys, ok := subsystems[name]
|
|
if !ok || !cgroups.PathExists(path) {
|
|
continue
|
|
}
|
|
if err := sys.Set(path, container.Cgroups); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func getUnitName(c *configs.Cgroup) string {
|
|
return fmt.Sprintf("%s-%s.scope", c.Parent, c.Name)
|
|
}
|
|
|
|
// Atm we can't use the systemd device support because of two missing things:
|
|
// * Support for wildcards to allow mknod on any device
|
|
// * Support for wildcards to allow /dev/pts support
|
|
//
|
|
// The second is available in more recent systemd as "char-pts", but not in e.g. v208 which is
|
|
// in wide use. When both these are available we will be able to switch, but need to keep the old
|
|
// implementation for backwards compat.
|
|
//
|
|
// Note: we can't use systemd to set up the initial limits, and then change the cgroup
|
|
// because systemd will re-write the device settings if it needs to re-apply the cgroup context.
|
|
// This happens at least for v208 when any sibling unit is started.
|
|
func joinDevices(c *configs.Cgroup, pid int) error {
|
|
path, err := join(c, "devices", pid)
|
|
// Even if it's `not found` error, we'll return err because devices cgroup
|
|
// is hard requirement for container security.
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
devices := subsystems["devices"]
|
|
return devices.Set(path, c)
|
|
}
|
|
|
|
func setKernelMemory(c *configs.Cgroup) error {
|
|
path, err := getSubsystemPath(c, "memory")
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
|
|
if err := os.MkdirAll(path, 0755); err != nil {
|
|
return err
|
|
}
|
|
|
|
if c.KernelMemory > 0 {
|
|
err = writeFile(path, "memory.kmem.limit_in_bytes", strconv.FormatInt(c.KernelMemory, 10))
|
|
if err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func joinMemory(c *configs.Cgroup, pid int) error {
|
|
path, err := getSubsystemPath(c, "memory")
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
|
|
// -1 disables memoryswap
|
|
if c.MemorySwap > 0 {
|
|
err = writeFile(path, "memory.memsw.limit_in_bytes", strconv.FormatInt(c.MemorySwap, 10))
|
|
if err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.OomKillDisable {
|
|
if err := writeFile(path, "memory.oom_control", "1"); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
if c.MemorySwappiness >= 0 && c.MemorySwappiness <= 100 {
|
|
err = writeFile(path, "memory.swappiness", strconv.FormatInt(c.MemorySwappiness, 10))
|
|
if err != nil {
|
|
return err
|
|
}
|
|
} else if c.MemorySwappiness == -1 {
|
|
return nil
|
|
} else {
|
|
return fmt.Errorf("invalid value:%d. valid memory swappiness range is 0-100", c.MemorySwappiness)
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
// systemd does not atm set up the cpuset controller, so we must manually
|
|
// join it. Additionally that is a very finicky controller where each
|
|
// level must have a full setup as the default for a new directory is "no cpus"
|
|
func joinCpuset(c *configs.Cgroup, pid int) error {
|
|
path, err := getSubsystemPath(c, "cpuset")
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
|
|
s := &fs.CpusetGroup{}
|
|
|
|
return s.ApplyDir(path, c, pid)
|
|
}
|
|
|
|
// `BlockIODeviceWeight` property of systemd does not work properly, and systemd
|
|
// expects device path instead of major minor numbers, which is also confusing
|
|
// for users. So we use fs work around for now.
|
|
func joinBlkio(c *configs.Cgroup, pid int) error {
|
|
path, err := getSubsystemPath(c, "blkio")
|
|
if err != nil {
|
|
return err
|
|
}
|
|
if c.BlkioWeightDevice != "" {
|
|
if err := writeFile(path, "blkio.weight_device", c.BlkioWeightDevice); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.BlkioThrottleReadBpsDevice != "" {
|
|
if err := writeFile(path, "blkio.throttle.read_bps_device", c.BlkioThrottleReadBpsDevice); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.BlkioThrottleWriteBpsDevice != "" {
|
|
if err := writeFile(path, "blkio.throttle.write_bps_device", c.BlkioThrottleWriteBpsDevice); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.BlkioThrottleReadIOpsDevice != "" {
|
|
if err := writeFile(path, "blkio.throttle.read_iops_device", c.BlkioThrottleReadIOpsDevice); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if c.BlkioThrottleWriteIOpsDevice != "" {
|
|
if err := writeFile(path, "blkio.throttle.write_iops_device", c.BlkioThrottleWriteIOpsDevice); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func joinHugetlb(c *configs.Cgroup, pid int) error {
|
|
path, err := join(c, "hugetlb", pid)
|
|
if err != nil && !cgroups.IsNotFound(err) {
|
|
return err
|
|
}
|
|
|
|
hugetlb := subsystems["hugetlb"]
|
|