Fixes#11104.
See the issue for a description of the problem.
Now, we use the same logic for initial conftest paths as we do for
deciding the initial args, which was the idea behind checking
`namespace.file_or_dir` and `testpaths` previously.
This fixes the issue of `testpaths` being considered for initial
conftests even when it's not used for the args.
(Another issue in faeb16146b was that the
`testpaths` were not glob-expanded, this is also fixed.)
Currently, if `--confcutdir` is not set, `inipath.parent` is used, and
if `initpath` is not set, then `confcutdir` is None, which means there
is no cutoff.
Having no cutoff is not great, it means we potentially start probing
stuff all the way up to the filesystem root directory. So let's add
another fallback, to `rootpath`, which is always something reasonable.
The change from `path not in confuctdir.parents` to the `relative_to`
check in 0c98f19231 broke picking up
conftest files when running against an installed package/site-packages.
See the issue for more details.
Fix#9767.
* Rename pytest_ignore_collect fspath parameter to collection_path
* Rename pytest_collect_file fspath parameter to file_path
* Rename pytest_pycollect_makemodule fspath parameter to module_path
* Rename pytest_report_header startpath parameter to start_path
* Rename pytest_report_collectionfinish startpath parameter to start_path
* Update docs with the renamed parameters
* Use pytest-flakes fork temporarily to prove it works
* Use pytest-flakes 4.0.5
Part of reducing dependency on `py`. Also enables upcoming improvements.
In cases where there are simpler alternatives (in tests), I used those.
What's left are a couple of uses in `_pytest.main` and `_pytest.python`
and they only have modest requirements, so all of the featureful code
from py is not needed.
ExitCode is used in several internal modules and hooks and so with type
annotations added, needs to be imported a lot.
_pytest.main, being the entry point, generally sits at the top of the
import tree.
So, it's not great to have ExitCode defined in _pytest.main, because it
will cause a lot of import cycles once type annotations are added (in
fact there is already one, which this change removes).
Move it to _pytest.config instead.
_pytest.main still imports ExitCode, so importing from there still
works, although external users should really be importing from `pytest`.
Using Path().resolve() is better than py.path.realpath because
it resolves to the correct path/drive in case-insensitive file systems (#5792):
>>> from py.path import local
>>> from pathlib import Path
>>>
>>> local('d:\\projects').realpath()
local('d:\\projects')
>>> Path('d:\\projects').resolve()
WindowsPath('D:/projects')
Fix#5819
It doesn't seem to add much value (why would one execute tests
based on that marker?), plus using the docstring for that
encourages one to write a more descriptive message about the test
Also renames `_path2confmods` to `_dirpath2confmods` for clarity (it is
expected to be a dirpath in `_importconftest`).
Uses an explicit maxsize, since it appears to be only relevant for a
short period [1].
Removes the lru_cache on _getconftest_pathlist, which makes no
difference when caching _getconftestmodules, at least with the
performance test of 100x10 files (#4237).
1: https://github.com/pytest-dev/pytest/pull/4237#discussion_r228528007
This fixes running `pytest tests/test_foo.py::test_bar`, where `tests`
is a symlink to `project/app/tests`: previously
`project/app/conftest.py` would be ignored for fixtures then.
This will now issue a RemovedInPytest4Warning when the user calls
a fixture function directly, instead of requesting it from test
functions as is expected
Fix#3661